المستودع الرقمي في جامعة الإخوة منتوري قسنطينة 1

Contribution à l’intensification des transferts thermiques par un nanofluide dans un échangeur thermique à tube elliptique coaxial.

عرض سجل المادة البسيط

dc.contributor.author Bouzerzour, Abdeslem
dc.contributor.author Djezzar, Mahfoud
dc.date.accessioned 2022-05-25T09:04:39Z
dc.date.available 2022-05-25T09:04:39Z
dc.date.issued 2020-10-20
dc.identifier.uri http://depot.umc.edu.dz/handle/123456789/9592
dc.description.abstract The author presents here, a contribution to the study of two-dimensional laminar natural convection of Newtonian incompressible nanofluids confined in coaxial elliptical tubes heat exchanger. The external wall is maintained cold while the internal wall is subjected to different parietal thermal conditions. The effects of inclination angle and the injected nanoparticles type are examined for considered, Rayleigh number and volume fraction, values. A numerical code with finite volumes method based on Vorticity-Stream function formulation is developed to resolve the continuity, momentum, and energy equations written in elliptic coordinates considering Boussinesq approximation. The study consists of three parts, for different Rayleigh numbers (103<Ra<105) and volume fractions (0<<0.08). In the first part, the internal wall of the Cu/Water nanofluid filled annulus is partially heated while the external one is cold. Three different parietal thermal conditions are considered. In the first one, a constant temperature is imposed on the top and the bottom of the internal wall. Secondly, the same temperature is imposed on the right and left sides of this wall and finally, the right top and the left bottom of the wall are the heated areas. The areas kept cold in the three cases are at the same temperature as the external wall. For the second part, both walls of the Cu/Water filled annulus are kept at uniform temperatures, the internal hot and the external cold. The effect of the inclination angle α, for values 0°, 10°, 45°, 60° et 90°, is highlighted. A comparison of Cu/Water, Ag/Water and Al2O3/Water performances in our annular space when α=90°, has been established for the third part. The obtained numerical results, presented as mean and local Nusselt numbers profiles as well as isotherms and streamlines contours, show that adding nanoparticles to base fluid contribute to heat transfer enhancement.
dc.language.iso fr
dc.publisher Université Frères Mentouri - Constantine 1
dc.subject physique: Energies Renouvelables
dc.subject Transferts de chaleur
dc.subject Convection naturelle
dc.subject Espace annulaire elliptique
dc.subject Formulation vorticité-fonction de courant
dc.subject nanofluide
dc.subject chauffage partiel
dc.subject Heat transfers
dc.subject Natural convection
dc.subject Elliptical annular space
dc.subject Vorticity-Stream function formulation
dc.subject nanofluid
dc.subject partial heating
dc.subject نقل الحرارة
dc.subject الحمل الحراري الطبيعي
dc.subject الحيز الحلقي الإهليليجي
dc.subject صياغة التدويم-دالة التيار
dc.subject مائع نانومتري
dc.subject التسخين الجزئي
dc.title Contribution à l’intensification des transferts thermiques par un nanofluide dans un échangeur thermique à tube elliptique coaxial.
dc.type Thesis


الملفات في هذه المادة

هذه المادة تظهر في الحاويات التالية

عرض سجل المادة البسيط

بحث دي سبيس


استعرض

حسابي