DSpace Repository

Analyse des performances des convertisseurs statiques commandés par le contrôle direct de puissance (DPC)

Show simple item record

dc.contributor.author Medouce, Houssam Eddine
dc.contributor.author Benalla, Hocine
dc.date.accessioned 2022-05-24T10:04:05Z
dc.date.available 2022-05-24T10:04:05Z
dc.date.issued 2018-07-03
dc.identifier.uri http://depot.umc.edu.dz/handle/123456789/6072
dc.description.abstract This work deals with the analysis, design, and control of grid-interfaced permanent magnet synchronous generator (PMSG) based variable speed wind energy conversion system (WECS) for power smoothening with maximum power point tracking (MPPT) and power quality conditioning capabilities. The power electronic device used usually as intermediate between the wind generator and the grid is a full rated two levels back to back converter (BTB). The BTB converter is constituted of tow PWM converters, the machine side converter (CCM) works as a rectifier and the grid side converter works as an inverter. Several DPC based control techniques (conventional DPC, predictive DPC and DPC based sliding mode approach (DPC-SMC)) have been applied on a PWM rectifier under ideal and disturbed supply voltage conditions. Moreover, the sensorless grid voltage control scheme is presented using sliding mode estimator. Two versions of sliding mode estimator have been implemented, one for the ideal and the other for the disturbed supply condition. After an extensive set of simulations following by experimental validation, the grid voltage sensorless DPC-SMC technique has been introduced the best performance with high estimation accuracy and power quality. On the other hand, in a wind energy conversion system, the grid side inverter function is ensuring permanent and stable transmission of energy to the grid. However, the extensive use of nonlinear loads led to decrease the quality of energy at the point of common coupling (PCC). Thus, the idea is to extend the inverter function with a harmonic compensation capability. Hence, analysis, design, and control of shunt active power filter (SAPF) under ideal and disturbed supply voltage conditions were an important part of this thesis. Then, an improved control circuit for SAPF system based on DPC concept combined with a Kalman filter as synchronization technique has been introduced. Furthermore, a modified voltage sensorless DPC concept based predictive model and modified sliding mode estimator has been proposed to be applied for a SAPF. Finally, the overall circuit control of the WECS system is based on the optimal findings, which are developed in this work. For the CCM and CCR converters, we have been applied the DPC-SMC and the proposed DPC approach respectively, as optimized solutions.
dc.language.iso fr
dc.publisher Université Frères Mentouri - Constantine 1
dc.subject PMSG
dc.subject WECS
dc.subject Commande direct de puissance (DPC)
dc.subject redresseur MLI
dc.subject filtre actif de puissance parallèle
dc.subject filtre de Kalman
dc.subject mode glissant
dc.subject réseau électrique perturbé
dc.subject Direct power control (DPC)
dc.subject PWM rectifier
dc.subject Shunt active power filter
dc.subject Kalman filter
dc.subject sliding mode
dc.subject disturbed supply
dc.subject مولد كهربائي متزامن
dc.subject نظام تحويل طاقة الرياح متعدد السرعات(PMSG)
dc.subject تقنية التحكم في الاستطاعة المباشر (DPC)
dc.subject مقوم
dc.subject مرشح فعال
dc.subject وضع الانزلاق
dc.subject شبكة كهربائية مضطربة
dc.title Analyse des performances des convertisseurs statiques commandés par le contrôle direct de puissance (DPC)
dc.title cas d’une centrale éolienne connectée au réseau électrique.
dc.type Thesis


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account